Ariston boilers brand themselves as a ‘Global leader in thermic comfort and energy efficiency’, but can they back up their buzzword laden catchphrase with boilers that perform?
If you’re reading this article on Ariston Boiler Error/Fault Codes then you’re probably not feeling too positive that they do. However, like any appliance, at some point, they will start to encounter issues. Whether it’s down to old age or poor manufacturing.
The Ariston brand belongs to Ariston Thermo Group, a group that celebrated its 90th anniversary in 2020. So they are an extremely well-established brand, founded by Aristide Merloni, an Italian industrial pioneer.
Ariston are extremely focused on sustainability, which is good to hear, especially in today’s current climate.
Ariston boilers don’t have a great reputation amongst heating engineers as being particularly reliable, but heating engineers all have different opinions on what boilers are good or bad. So what do customers think about Ariston boilers?
If we take a look at their reviews over on Trustpilot, it looks like they back up the general consensus among heating engineers with a very disappointing 2.8 out of 5.
When you’re looking to spend out on a new boiler you would want a little more confidence in your new boiler than this rating would give. They don’t respond to the majority of their negative reviews either, which as a customer would make you feel like they don’t care when something goes wrong.
Ariston offers a range of combi boilers, system boilers, and heat only (regular) boilers. Their combi range offers between 24 – 38kW boilers which cater from anything between a small flat and a large house. Their system boilers range between 18 – 30kW and the heat only has just one boiler available (24kW).
Now that you have a bit of background on Ariston boilers, let’s get into the Ariston error codes. We provide these error codes to help you identify the issue with your boiler and hopefully fix it yourself. If you identify an internal issue with your Ariston boiler then you will need to contact a Gas Safe Engineer to come and take a look.
Generally, Ariston boilers only come with a short guarantee/warranty length, so there’s a good chance you’re out of warranty. If not, get in touch with Ariston and see if you can get them out to take a look (and hopefully fix) your boiler.
If your boiler is out of warranty, rather than put money into fixing it might be worth getting a quote on a new boiler, give WarmZilla a try. Prices start from £1489 including installation, wireless controls, system cleanse, system filter, and a guarantee lasting between 5 – 10 years depending on which boiler model you select.
WarmZilla offer boiler finance starting from as little as £9.80 per month, with 0% interest over 2 years on selected boilers. Our lenders have a very high acceptance rate, even if you have a bad credit history.
Sounds great, doesn’t it? Well, we can top this! We also offer a Boiler Comparison tool that allows you to compare up to three boiler models or brands at one time, to help you find the perfect new boiler for your home.
Now, back to the Ariston boilers. Check out the table below to find your error code and see what the fault code on your Ariston boiler relates to. Ariston fault codes are generally the same across all their boilers, which makes it easier to identify the issue with your boiler.
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Central Heating Circuit Issues | ||
101 | All Boilers | Overheat |
102 | E-Combi Evo E-System Evo Clas He Evo (Combi and system) | Pressure sensor error |
103 | All Boilers | Insufficient circulation |
104 | All Boilers | Insufficient circulation |
105 | All Boilers | Insufficient circulation |
106 | All Boilers | Insufficient circulation |
107 | All Boilers | Insufficient circulation |
108 | All Combi Boilers | Insufficient water (request filling) |
109 | Clas net one / Clas one Combi Clas system one | System pressure greater than 3 bar |
110 | All Boilers | Central heating Flow temperature probe circuit open/short circuit |
112 | All Boilers | Central heating Flow temperature probe circuit open/short circuit |
114 | All Boilers | External sensor circuit open/short circuit |
116 | All Combi and System Boilers | Floor thermostat contact open |
118 | All Boilers | Heating delivery probe problem |
1p1 | All Boilers | Insufficient circulation indication |
1p2 | All Boilers | Insufficient circulation indication |
1p3 | All Boilers | Insufficient circulation indication |
1p4 | Clas Net one Combi Clas one Combi Clas System one | Insufficient circulation indication |
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Hot Water Circuit Issues | ||
202 | Clas HE evo Clas he evo system E-combi evo E-system evo | 2 bottom storage temperature probe open/short circuit |
204 | Clas HE evo Clas he evo system E-combi evo E-system evo | Solar collector temperature probe open/short circuit |
205 | E-combi one E-System one Clas Net one Combi Clas one Combi | Domestic hot water in probe open circuit |
207 | Clas HE evo Clas he evo system E-combi evo E-system evo | Solar collector overheating |
208 | Clas HE evo Clas he evo system E-combi evo E-system evo | Collector frost protection temperature |
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Internal Printed Circuit Board (PCB) Issues | ||
301 | All Boilers | EEPROM error |
302 | All Boilers | Communication error |
303 | All Boilers | Main printed circuit board (PCB) error |
304 | All Boilers | Too many resets (> 5) in 15 minutes |
305 | All Boilers | Main printed circuit board (PCB) error |
306 | All Boilers | Main printed circuit board (PCB) error |
307 | All Boilers | Main printed circuit board (PCB) error |
3p9 | E-combi one E-System one Clas Net one Combi Clas one Combi Clas System one | Schedule service |
External Printed Circuit Board (PCB) Issues | ||
407 | Clas HE evo Clas he evo system E-combi evo E-system evo | 7 Room sensor circuit open/short circuit |
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Ignition & Detection Issues | ||
501 | All Boilers | No flame detected |
502 | All Boilers | Flame detected with gas valve closed |
504 | All Boilers | Flame lift |
5p1 | All Boilers | 1st ignition failed |
5p3 | All Boilers | 2nd ignition failed |
5p4 | All Boilers | Flame cut-off |
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Air Inlet / Flue / Gas Outlet Issues | ||
604 | CLAS HE R E-Combi Evo E-System EVO Clas HE evo Combi Clas HE evo System | Insufficient fan speed |
610 | All Boilers | Thermofuse open |
612 | Clas HE Evo Combi Clas He Evo System E-Combi Evo E-system Evo Clas net one combi Clas one combi Clas system one | Fan speed has incorrect measurement |
Fault Code | Boiler Model | Possible Cause |
---|---|---|
Multi-Zone Heating Issues | ||
701 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 2 outgoing sensor defective |
702 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 2 return sensor defective |
703 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 3 outgoing sensor defective |
704 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 3 return sensor defective |
705 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Hydraulic separation sensor defective |
706 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 2 overheating |
707 | E-Combi Evo E-System EVO Clas HE evo combi Clas he evo system | Zone 3 overheating |
Not your first time here?
Maybe it's time for a new boiler. Drop your details below, and we'll support you throughout your boiler journy (as well as £50 off - no strings attached).
Ariston System Boiler Error / Fault Codes - Clas Net One, Clas One, E-Combi and E-System Boilers
Fault Code | Boiler Model | Possible Cause |
---|---|---|
External Printed Circuit Board (PCB) Issues | ||
411 | Clas Net one Clas one E System | Room sensor circuit open or short circuit zone 1 |
412 | Clas Net one Clas one E System | Room sensor circuit open or short circuit zone 2 |
414 | Clas Net one Clas one E System | Room sensor circuit open or short circuit zone 3 |
Multi-Zone Heating | ||
701 | Clas Net one Clas one E System | Send sensor defective (Zone 1) |
702 | Clas Net one Clas one E System | Send sensor defective (Zone 2) |
703 | Clas Net one Clas one E System | Send sensor defective (Zone 3) |
711 | Clas Net one Clas one E System | Return sensor defective (zone 1) |
712 | Clas Net one Clas one E System | Return sensor defective (zone 2) |
713 | Clas Net one Clas one E System | Return sensor defective (zone 3) |
722 | Clas Net one Clas one E System | Overheating in zone 2 |
723 | Clas Net one Clas one E System | Overheating in zone 3 |
750 | Clas Net one Clas one E System | All heating zones locked |
Below is a complete list of Ariston boiler manuals courtesy of our friends over at freeboilermanuals.com.
- Ariston ACO 35 MFFi
- Ariston ACO Type C
- Ariston Challenger 80e
- Ariston CLAS NET One 24
- Ariston CLAS NET One 30
- Ariston CLAS NET One 38
- Ariston CLAS ONE 24
- Ariston CLAS ONE 30
- Ariston CLAS ONE 38
- Ariston Clas 24FF
- Ariston Clas 30FF
- Ariston Clas System 24FF
- Ariston Clas System 28FF
- Ariston CLAS HE 24
- Ariston CLAS HE 30
- Ariston CLAS HE 38
- Ariston CLAS HE R12
- Ariston CLAS HE R18
- Ariston CLAS HE R24
- Ariston CLAS HE EVO24
- Ariston CLAS HE EVO30
- Ariston CLAS HE EVO38
- Ariston CLAS HE EVO 24kw ErP compliant
- Ariston CLAS HE EVO 30kw ErP compliant
- Ariston CLAS HE EVO 38kw ErP compliant
- Ariston CLAS HE EVO 18kw system Erp
- Ariston CLAS HE EVO 24kw system ErP
- Ariston CLAS HE EVO 30kw system ErP
- Ariston CLAS HE EVO system 18
- Ariston CLAS HE EVO system 24
- Ariston CLAS HE EVO system 30
- Ariston CLAS SYSTEM One 18
- Ariston CLAS SYSTEM One 24
- Ariston CLAS SYSTEM One 30
- Ariston CLAS 24 FF
- Ariston CLAS 30 FF
- Ariston CLAS System 21 FF
- Ariston CLAS System 28 FF
- Ariston Compact 400 20/1MFS
- Ariston GENUS HE system 24
- Ariston GENUS HE system 30
- Ariston GENUS 30 Plus
- Ariston CLAS HE R12
- Ariston CLAS HE R18
- Ariston CLAS HE R24
- Ariston Combi A 24 MFFi
- Ariston Combi A 30 MFFi
- Ariston Dia 20 MI CE
- Ariston Dia 24 MI CE
- Ariston Dia 20 MFFICE
- Ariston Dia System 27 RFFi
- Ariston E-Combi ONE 24
- Ariston E-Combi ONE 30
- Ariston E-Combi 24
- Ariston E-Combi 30
- Ariston E-Combi 38
- Ariston E-Combi EVO 24
- Ariston E-Combi EVO 30
- Ariston E-Combi EVO 38
- Ariston E-Combi EVO 24 Erp
- Ariston E-Combi EVO 30 ErP
- Ariston E-Combi EVO 38 ErP
- Ariston Egis HE 24
- Ariston Egis HE 30
- Ariston E-System ONE 24
- Ariston E-System ONE 30
- Ariston E-System EVO 24 ErP
- Ariston E-System EVO 30 ErP
- Ariston Eco Genus
- Ariston Eco Genus
- Ariston Euro Combi A23 MFFi
- Ariston Euro Combi A27 MFFi
- Ariston Euro Combi STYX
- Ariston E-System EVO 24
- Ariston E-System EVO 30
- Ariston Excalibur 80
- Ariston Excalibur 100
- Ariston Genus 23 MFFi
- Ariston Genus 27 MFFi
- Ariston Genus 30 MFFi
- Ariston Genus 27 RFFi
- Ariston Genus 27 Plus
- Ariston Genus 30 Plus
- Ariston Genus 27 BFFi
- Ariston Genus HE 35 +
- Ariston GENUS HE24
- Ariston GENUS HE30
- Ariston GENUS HE38
- Ariston Intesa TP 23
- Ariston Intesa TP 30
- Ariston 20 M wall hung combi
- Ariston 20 MFS4wall hung combi
- Ariston 24/1 ME wall hung combi
- Ariston 24/1 MFS wall hung combi
- Ariston Micro condens combi 27 MFFi
- Ariston Micro condens system 27 RFFi
- Ariston Micro Combi 23 MFFi
- Ariston Micro Combi 27 MFFi
- Ariston Micro Genus 23 MFFI
- Ariston microGENUS HE 24MFFI
- Ariston microGENUS HE 28MFFI
- Ariston microGENUS HE 32MFFI
- Ariston microGENUS 23
- Ariston MicroGENUS 11 24 MFFI
- Ariston MicroGENUS 11 28 MFFI
- Ariston MicroGENUS 11 31 MFFI
- Ariston STYX Sx 20M
- Ariston STYX Sx 20MFF
- Ariston System A 24
- Ariston System A 30
- Ariston Micro System Type C
- Ariston Type C boiler
- Ariston ACO Series 27 MFFI
- Ariston ACO Series 32 MFFI
- Ariston ACO Series 27 RFFI
- Ariston ACO Series 32 RFFI
- Ariston Type C boiler micro system
- Ariston Type C boiler micro system