Baxi Boiler Error Codes / Fault Codes List Re October 2, 2020

Baxi Boiler Error Codes / Fault Codes List

Baxi Boiler

Baxi boilers are normally quite a reliable brand of boiler, but even the most reliable boilers sometimes encounter an issue. When your Baxi boiler encounters an error, it will lockout to prevent any further harm coming to you or, even worse, the boiler (it’s an expensive bit of kit).

When your Baxi locks out, an error code will be displayed on the LCD screen to help you identify what the issue is. The fault codes are listed in your boiler manual but it’s probably just easier to Google the error code and get the answer right here on the WarmZilla website.

Some faults you will be able to fix yourself but some will require a Gas Safe registered engineer to look at. This guide is intended to help you identify your boiler issue so you can get a rough idea of the costs to fix it, it is illegal to open the casing of your boiler and attempt to fix it yourself.

If your boiler isn’t working but it isn’t displaying a fault code either then check your water, gas, and electricity supplies to ensure there is no issue with supply. If you have a prepay meter, make sure you have credit. Check your property has running water from the cold taps, that your gas is working by lighting the hob or gas fire and that your electricity is working by turning on a light. Your boiler may be on a separate circuit, so if the rest of your home has electricity but the LCD display on your boiler isn’t displaying anything your boiler may not be receiving power and you may need to call an electrician or Gas Safe engineer.

If your boiler is getting on in years and you would like a quote on a new boiler, then give WarmZilla a try. Prices start from £1,489 including installation, wireless controls, system cleanse, system filter, and a guarantee lasting between 5 & 10 years depending on which boiler model you select. Just answer a few simple questions about your home and you will be given a selection of boilers suitable for your needs in just a few minutes.

WarmZilla offers boiler finance starting from as little as £9.80 per month, with 0% interest over 2 years on selected boilers. Our lenders have a very high acceptance rate, even if you have a bad credit history.

If you are unsure about what boiler is the most suitable for your home, why not try out our Boiler Comparison tool that allows you to compare up to three boiler models or brands at one time, to help you find the perfect boiler. 

Hopefully, it won’t cost much to get your Baxi boiler fixed but it may be worthwhile getting a WarmZilla boiler quote so you can weigh up your options.

BAXI 200 COMBI / BAXI 400 COMBI Boiler Error/Fault Codes

Error Code

Possible Fault

H.01 – .00

Temporary Fault – Temporary loss of communication between the gas valve and boiler board. Fault in air/gas unit.

Loose connection to the gas valve.

H.01 – .05

Temporary Fault – Maximum difference between the flow and return temperature exceeded. Non-existent or insufficient circulation. Sensor error.

H.01 – .08

Temporary Fault – Flow temperature increasing too fast in heating mode. Non-existent or insufficient circulation.
Sensor error.

H.01 – .14

Temporary Fault – Maximum flow temperature value exceeded. Non-existent or insufficient circulation. Non-existent or insufficient circulation.

H.01 – .18

Temporary Fault – No circulation of water. Non-existent or insufficient circulation. Sensor error.

H.01 – .21

Temporary Fault – Flow temperature increasing too fast in DHW mode. Non-existent or insufficient circulation. Sensor error.

H.02 – .02

Temporary Fault – No input of parameters C1/C2. PCB not configured.

H.02 – .03

Temporary Fault– Incorrect configuration settings C1/C2.

H.02 – .04

Temporary Fault – Parameter error. Incorrect parameters.

H.02 – .06

Temporary Fault – System water pressure. Water leak on the boiler. Water leak on the system.

H.03 -.00

Temporary Fault – Communication error with NTC flue sensor. Sensor not, or badly connected. Bad connection. Sensor fault.

H.03 -.01

Temporary Fault – Communication error with the HMI PCB. HMI is not connected.

H.03 -.02

Temporary Fault – No flame during operation. No ionization current.

E.00 – .04

Permanent Fault – Return temperature sensor open-circuit. Sensor not or badly connected. Bad connection. Sensor fault.

E.00 – .05

Permanent Fault – Return temperature sensor open-circuit. Sensor not or badly connected. Bad connection. Sensor fault.

E.01 – .02

Permanent Fault – Temperature measured by return sensor greater than flow sensor. Bad connection. Sensor fault. Sensor not or badly connected.

E.01 – .04

Permanent Fault – Loss of flame detected 5 times in 24 hours (With burner on). No ionization current.

E.01 – .11

Permanent Fault Requiring Reset – Incorrect fan speed. External draught over the boiler. Defective gas/air unit.

E.01 – .12

Permanent Fault Requiring Reset – Temperature measured by return sensor greater than flow temperature.

E.01 – .17

Permanent Fault Requiring Reset – No circulation. Sensor not or badly connected. Sensor fault.

E.01 – .20

Permanent Fault – Maximum flue gas temperature value reached (>140 Deg C). No circulation. Sensor fault.

E.02 – .00

Permanent Fault – Boiler reset in progress. Reset button has been pressed.

E.02 – .07

No or low system water pressure. Low system pressure (less than 0.5bar) boiler will not function.

E.02 – .16

Permanent Fault – Onboard CSU time-out. Check PCB for damage.

E.02 – .17

Permanent Fault – Permanent loss of communication between the gas valve and boiler PCB. Fault in air/gas unit. Loose connection to the gas valve.

E.02 – .19

Permanent Fault – Jumper 1 changed. Check the position of jumper 1.

E.02 – .20

Permanent Fault – Jumper 2 changed. Check the position of jumper 2.

E.02 – .21

Permanent Fault – Jumper 3 changed. Check the position of jumper 3.

E.02 – .47

Permanent Fault – Connection to external device unsuccessful. Check wiring to external device.

E.02 – .48

Permanent Fault – Configuration to external device unsuccessful. Check pairing to external.

E.04 – .00

Permanent Fault – Gas valve fault. Gas valve not detected.

E.04 – .01

Permanent Fault – Flow temperature sensor short-circuited. Sensor not or badly connected. Bad connection. Sensor fault.

E.04 – .02

Permanent Fault – Flow temperature sensor open-circuited. Sensor not or badly connected. Bad connection. Sensor fault.

E.04 – .03

Permanent Fault – Critical flow temperature reached. Non-existent or insufficient circulation.

E.04 – .04

Permanent Fault – Flue temperature sensor short-circuited. Sensor not or badly connected. Bad connection. Sensor fault.

E.04 – .05

Permanent Fault – Flue temperature sensor open-circuited. Sensor not or badly connected. Bad connection. Sensor fault.

E.04 – .06

Permanent Fault – Critical flue gas temperature value reached. No circulation. Sensor fault.

E.04 – .08

Permanent Fault – Maximum safe temperature value reached. (Safety thermostat open-circuited). No circulation. Sensor not or badly connected. Bad connection. Sensor fault.

E.04 – .10

Failure to light (could be gas supply issue).

E.04 – .12

Permanent Fault – False flame signal. Short-term fluctuation of the mains. Ionization current presents even though there is no flame. The burner remains very hot (CO2 is too high). Defective gas/air unit.

E.04 – .13

Permanent Fault – Fan rotor blocked. Fan seized. Wiring to fan damaged.

E.04 – .17

Permanent Fault – Problem with the gas valve. Defective gas/air unit.

 

BAXI PLATINUM+ 40KW Boiler Error/Fault Codes

Error Code

Possible Fault

E20

Central heating NTC fault

E28

Flue NTC fault, air pressure switch fault, blocked flue, blocked condensate, or wiring fault. 

E50

Hot water NTC fault

E110

E110 safety thermostat operated

E119

The water pressure switch was not operated

E125

Circulation fault (primary circuit)

E130

Flue NTC operated

E133

Interruption of gas supply or flame failure

E160

Fan or fan wiring Fault

E193

Pre-circulation fault

BAXI 600 COMBI / BAXI 800 COMBI Boiler Error/Fault Codes

Error Code

Possible Fault

E09

Gas valve connection cable.

E10

External probe fault.

E12

Differential water flow switch fault (still open).

E13

Differential water flow switch fault (still closed).

E15

Gas valve command fault.

E20

Central heating NTC fault.

E28

Flue NTC fault.

E40

Central heating return NTC fault.

E50

DHW NTC sensor fault (tank boiler) (s.c.) OR DHW NTC sensor fault (tank boiler) (o.c.).

E83/E84/E85/E86/E87

No communication.

E109

Pre-circulation fault.

E110

i) Boiler max temperature exceeded for gradient (probable pump jammed or air in the circuit). OR ii) Boiler max temperature exceeded for overtemperature (probable pump jammed or air in the circuit). OR iii) Safety thermostat sensor tripped.

E118

Primary system water pressure too low (< 0.5 bar).

E125

Circulation fault (primary).

E128

Frequent flame failure (12 times).

E129

Safety error for frequent loss of flame with max correction during the ignition during Calibration Function.

E130

Flue thermostat sensor tripped (lockout).

E133

Failure to light (could be a gas supply issue).

E134

Elapsed time gas valve open without gas (short request in a short period)

E135

Interruption of gas supply (internal error).

E154

Flow/return sensor temperature test.

E160

Fan or fan wiring fault

E163

Domestic Hot Water NTC sensor fault (s.c.) OR Domestic Hot Water NTC sensor fault (o.c.).

E270

Circulation fault (dry fire).

E317

Wrong power supply electrical frequency (Hz).

E321

Hot water NTC fault.

E384

False flame.

E385

Under voltage.

E430

Water pressure temporary test.

E430 + Flame ‘crossed’

Water pressure test failed.

BAXI 600 HEAT / MAIN ECO COMPACT HEAT Boiler Error/Fault Codes

Error Code

Possible Fault

1 flash green

Maximum flow temperature exceeded, Flow temperature rise rate too high, Excessive difference between, flow and return temperature

2 flashes green

BL terminals on User Interaction, Controller are open circuit

3 flashes green

No flame detected during operation

4 flashes green

Bad connection or wiring fault, Internal communication fault

5 flashes green

Parameter error or faulty PU, Configuration error or PCB fault

6 flashes green

Possible fault. Internal fault in combustion control unit

1 flash red

Bad connection to flow or return temperature sensor

2 flashes red

Over-temperature thermostat on heat exchanger activated, No water flow through heat exchanger, PCB over-temperature condition, Flue fault resulting in recirculation or activation of air pressure switch (if fitted)

3 flashes red

No ignition, No flame detected following ignition, False flame signal detected

4 flashes red

Fan calibration error, Fan failure

5 flashes red

Bad connection to PU, Parameter error or faulty PU

6 flashes red

Possible fault. Bad connection or wiring fault, Parameter error

BAXI 600 SYSTEM / BAXI 800 SYSTEM / BAXI 600 LPG Boiler Error/Fault Codes

Error Code

Possible Fault

E09

Gas valve connection cable

E15

Gas valve fault

E20

Central heating NTC fault

E28

Flue NTC fault

E40

Central heating return NTC fault

E83

Communication error

E109

Pre-circulation fault

E110

Safety thermostat operated

E118

Primary system water pressure too low

E125

Circulation fault (primary)

E128

Flame failure

E130

Flue NTC operated

E133

Interruption of gas supply or flame failure

E135

Interruption of gas supply (internal error)

E135

Interruption of gas supply (internal error)

E154

Flow/ return sensor temperature test

E160

Fan or fan wiring fault

E270

Circulation fault (Dry fire)

E321

Hot water NTC fault

E384

False flame

BAXI ECOBLUE (COMBI & SYSTEM) Boiler Error/Fault Codes

Error Code

Possible Fault

E10

Outdoor Sensor Error

E20

Central Heating Thermistor Sensor Fault

E28

Flue Thermistor Fault

E54

HW Flow Sensor Fault

E78

Water Pressure Sensor Fault

E100

Internal Clock Time Error on PCB

E109

Poor Circulation

110

Overheat

111

Maximum Limit of Flow Temperature

117

Water pressure too high

118

Water pressure too low

119

System Pressure Low (<0.5 bar)

125

Water circulation fault

127

Legionella Protection Temperature not reached

128

Loss of flame during operation

133

Safety time to establish flame exceeded

153

Forced reset unit unlocked

160

Fan Fault

162

Air pressure switch error

164

Heating flow switch error (Ireland) Pressure Sensor Error (UK)

166

Air Pressure Switch Fault

270

Dry Fire

432

Earth connector error

433

Heat exchanger temperature exceeded (greater than 95 degrees)

BAXI ECOBLUE (HEAT) Boiler Error/Fault Codes

Error Code

Possible Fault

1 Green flash

Boiler temperature reached. No action required.

3 Green flashes

Temporary flame loss. Boiler will self reset, if fault continues you will see 3 red flashes.

4 Green flashes

Communication error between printed circuit board (PCB) and control. Temporary error, will self reset.

5 Green flashes

Parameter error on printed circuit board (PCB). Temporary error, will self reset

6 Green flashes

Miscellaneous error. Temporary error, will self reset.

1 Red flash

Sensor Error; Sensor Fault, Temperature Fault or Flow Fault

2 Red flashes

Boiler overheat tripped

3 Red flashes

Ignition fault. Boiler has attempted to light 5 times and failed

4 Red flashes

Fan Fault

5 Red flashes

Parameter or PSU Error

6 Red flashes

Miscellaneous error.

BAXI DUO-TEC /MEGAFLO Boiler Error/Fault Codes

Error Code

Possible Fault

E10

Outdoor sensor error

E20

Central Heating Thermistor Senor Fault

E28

Flue Thermistor Fault

E110

Boiler Overheat. Ensure radiators are bled of air

E119

Low water pressure. Add water to the system via the filling loop

E125

Primary Water Circulation Fault. Ensure radiators are bled of air

E131

Flue overheat lock out. This may follow a power cut, try reset

E133

Ignition fault – Check gas is turned on, if prepayment meter check there is credit. If all ok and E133 persists – contact Engineer to visit & investigate

E160/E161

Fan Fault

E164

Fan Fault

E167

PCB Fault

E168

PCB lock out

E193

Circulation fault

BAXI SOLO (HEAT) Boiler Error/Fault Codes

Error Code

Possible Fault

Flash Flash On

Fan Fault

Flash Off Flash

Incoming Voltage less than 180V

Flash Off On

Overheat lockout

Flash On Flash

PCB fault

Flash On On

PCB fault

Off Off Off

No power supply

On Flash Flash

No circulation/dry fire

On Flash On

Thermistor fault

On Off flash

Live and neutral reversed

On Off On

Ignition lockout

On Off Flash

PCB fault

On Off Flash

Low voltage wiring harness fault

BAXI GA RANGE Boiler Error/Fault Codes

Error Code

Possible Fault

E4

Ignition failure

E09

Gas valve wiring fault

E10

Outdoor sensor error

E15

Gas valve connection fault

E20

Central heating thermistor sensor fault

E28

Flue thermistor fault

E40

Central heating return thermistor fault

E53

Flue obstruction

E55

Calibration required

E78

Water pressure sensor fault

E92

Combustion test alarm during auto-setting

E109

Poor circulation

E110

Boiler overheat tripped

E117

System pressure high (>2.9 Bar)

E118

System pressure low (< 0.5bar)

E125

Primary water circulation fault

E128

Loss of flame during operation

E129

Loss of flame during calibration

E133

Ignition fault

E135

Internal error

E154

Primary flow fault

E160

Fan fault

E270

Dry fire

E317

Wrong power supply (Hz)

E321

Not water thermistor fault

E384

Flame detected when gas valve off

E385

Low voltage (less than 195v)

BAXI AVANTA RANGE Boiler Error/Fault Codes

Error Code

Possible Fault

E0

Temperature sensor fault

E1

Boiler overheat tripped

E2

Poor circulation

E3

PCB fault

E4

Ignition failure

E10

Poor/No circulation

E12

PCB Fault

E13

Heat exchanger thermal fuse tripped

E83/84/85/86/87

Fan fault normally E8

BAXI MAIN ECO COMPACT HEAT Boiler Error/Fault Codes

Error Code

Possible Fault

1 Green Flash

Boiler temp reached

3 Green Flashes

Boiler temp reached.Temporary error, self-reset, if continues will go to 3 red flashes

3 Green Flashes

Temporary Flame Loss. Temporary error, self-reset, if continues will go to 3 red flashes

4 Green Flashes

Communication error between PCB and Control. Temporary error, self-reset.

5 Green Flashes

Parameter Error On PSU/PCB. Temporary error, self-reset.

6 Green Flashes

Miscellaneous Error. Temporary error, self-reset.

1 Red Flash

Sensor Error; Sensor Fault, Temperature Fault or Flow Fault

2 Red Flashes

Boiler overheat tripped

3 Red Flashes

Ignition fault. Boiler has attempted to light 5 times and failed

4 Red Flashes

Fan Fault

5 Red Flashes

Parameter or PSU Error

6 Red Flashes

Miscellaneous

BAXI 105 HE Boiler Error/Fault Codes

The Baxi 105 HE is a discontinued condensing combi boiler with an energy-efficiency rating of B. If you’re experiencing issues with your Baxi 105 HE boiler then, given its age, we would recommend upgrading it to a modern a-rated energy efficient boiler.

The Baxi 105 HE doesn’t display fault codes but the manual provides a fault-finding section to allow you, or more likely a Gas Safe engineer to identify the issue.