Ferroli Boiler Error / Fault Codes List Re April 12, 2021

Ferroli Boiler Error / Fault Codes List

Ferroli Fault Codes

Ferroli claims that it is the relentless consumer demand and the need to address climate change that keeps “Ferroli at the leading edge of appliance design”. Well, design may be a strong point for Ferroli boilers, but are they as reliable as they are aesthetically pleasing? If you’re reading this blog, you’re probably dubious about this claim.

Ferroli was established in 1955, by Dante Ferroli. The original head office is located in San Bonifacio, near the Italian city of Verona. Ferroli now operates in over 14 countries across Europe and Asia, becoming a known boiler manufacturer in the industry.

For over 60 years, Ferroli’s objective has been to drive innovations in the heating industry and produce highly efficient appliances, superbly built and suited to a wide range of specifications.

If you’re getting fed up with your boiler making strange noises or constantly flashing different lights at you, and think that any more money put into fixing your boiler would be wasted money; then get a new boiler quote from WarmZilla. Our online survey asks you a set of simple questions about your current boiler, and it will show you a list of boilers suitable for your heating needs. It only takes a few minutes. 

With WarmZilla you can pay for your boiler using our boiler finance options. 0% APR finance is available over 2 years on selected boiler models. We guarantee to offer the cheapest combi boilers on the market.

Ferroli admits taking great pride in their ability to offer amazing service at all times, stating that all products are “produced entirely in-house”, which allows for “complete control over the quality, delivery and all-important aftersales”. Their products and service being so good that in 2017, the Ferroli BlueHelix Tech 25C was voted Best Boiler and Best Purchase in the Italian magazine, AltroConsumo. 

If we take a look at their Trustpilot reviews, off the bat, they seem pretty good. With 3.9 out of 5 stars and over 70% of reviews being positive. However, when we delve a little deeper, the negative reviews consistently talk about poor efficiency and unreliability, going completely against Ferroi’s claims to be highly efficient and reliable. 

In 2021, Which? conducted an annual boiler survey, gathering results from 12,000 boiler owners and 166 heating engineers. The results took into consideration the daily user experience and expert opinion. Which? categorised the scores into;

  • Reliability Score
  • Customer Score
  • Engineer Recommendation
  • Build Quality
  • Availability of Parts
  • Ease of Fixing Faults 
  • Ease of Servicing

Ferroli was scored the lowest of all brands in the survey with an overall score of 35%, compared to other boiler brands such as Vokera, who scored at least 50%. When breaking the scores down, Ferroli received;

  • 3/5 Overall Reliability
  • 1/5 Engineer Recommendation Score 
  • 2/5 Consumer Score

Overall, a pretty bad rating. 

But I’m guessing you’re reading this blog, nodding your head, thinking, yes I already know. 

If you are looking for a brand new, reliable boiler, get a quote from WarmZilla today. Prices start from £1489 including installation, wireless controls, system cleanse, system filter, and a guarantee lasting between 5 – 10 years depending on which boiler model you select.

The aim of this blog is to help to identify the issues your boiler may be having, with a list of all error/fault codes with Ferroli boilers.

Check out the table below to find your error code and see what the fault code on your Ferroli boiler relates to.

Ferroli Boiler Error Codes

Fault CodeSystem Behaviour
A01Ignition error – possible electrode fault or power too low, no gas or excessive condensate level
A02Electrode or card error
A03

Heating sensor damaged, no water circulation or air in the system

F04Wrong card parameter setting
F05

Air pressure switch contact error – wrong flue baffle obstructed or not correctly sized

A06

No flame after the ignition phase – low pressure in gas system burner minimum pressure setting

F07

Air pressure switch error – contacts closed on activation of fan

A09Gas valve error – wiring could be disconnected or error with gas valve
F10Delivery sensor error, sensor damaged wiring shorted or disconnected
F11

Domestic hot water (DHW) sensor error – sensor damaged, wiring shorted or disconnected

A15

Fault F05 generated 5 times within the last 24 hours – possible error with the air pressure switch

A16

Gas valve error – wiring disconnected or faulty gas valve

A23

Card parameter error – possibly wrong card parameter setting

A24

Card parameter error – possibly wrong card parameter setting

F34Supply voltage under 170V – electric mains error
F35Faulty mains frequency – electric mains error
F37

Error with system water pressure, possible pressure too low or water pressure switch is damaged

F43

Exchanger protection intervention – could be because no system water circulation or there’s air in the system

F50

Controller DBM23B error – controller could have an internal error

F51Controller DBM23B error – controller could have an internal error

Ferroli Bluehelix Tech Error Codes

Fault CodeSystem BehaviourPossible cause
A01No burner ignition

No gas or ignition – issue with detection electrode, faulty gas valve or insufficient gas supply pressure

A02Flame signal present with burner offElectrode error or PCB error
A05Fan errorNo 230V power supply or tachometric signal interrupted fan damaged or out of balance
A06No flame after the ignition phase

Ionisation electrode fault – flame unstable or air/flue ducts obstructed or condensate trap or pipes blocked

F07 – F14 – A07High flue gas temperatureThe flue gas probe detects excessive temperature
F08 – A08

Overtemperature protection intervention

Heating sensor damaged – no water circulation in the system or air in the system
F09 – A09

Overtemperature protection intervention

Return sensor damaged – no water circulation in the system or air in the system
F10 – A10Flow sensor errorSensor damaged – wiring shorted or wiring disconnected
F11 – A11Return sensor faultSensor damaged – wiring shorted or wiring disconnected
F12DHW sensor errorSensor damaged – wiring shorted or wiring disconnected
F13 – A13Flue probe fault

Probe damaged – wiring shorted or wiring disconnected

A14

Flue extraction duct safety device intervention


 
Fault F07 generated 3 times in the last 24 hours
F34

Supply voltage under 170V

Electric mains trouble
F37

Incorrect system water pressure

Pressure too low – water pressure switch either damaged, blocked or not connected
F39Optional external probe errorProbe damaged or wiring shorted – probe disconnected after activating the outside temperature mode
F41

Activation of maximum ELTA T protection

Heating sensor damaged, return sensor damaged, no water circulation as air in the system
F42 – A42Sensor control protection activationHeating sensor damaged, return sensor damaged or disconnected
F43

Exchanger protection intervention

No system water circulation – air in system
A23 – A24 – A26 – F15 – F21 – F40 – F47 – F50 – F51 – F53Printed circuit board (PCB) parameter faultWrong PCB parameter setting
F56 – A56

Calibration error/calibration procedure not completed

Incorrect parameters electrode damaged or not correctly positioned
F61 – A61

Printed circuit board (PCB) AGC01 error

PCB AGC01 internal error
A54 – A55 – A63

Printed circuit board (PCB) AGC01 fault

PCB AGC01 fault
F67Boiler chip card (BCC) service key connected
F68 – A68Boiler chip card (BCC) service key faultError loading BCC service key file
A62

No communication between PCB and gas valve

PCB not connected – valve damaged, replace the valve
A64

Maximum number of consecutive resets exceeded

Maximum number of consecutive resets exceeded
F66Firmware not loaded successfully

Ferroli Modena HE System Error Codes

Fault CodeSystem Behaviour
A01No burner ignition – possible electrode error, defective gas valve or incorrect inlet gas pressure
A02Flame detected with the burner off – electrode defective main board defective
A03High limit protection – possible flow temperature sensor not active or incorrectly located, no system circulation
A04

Flue gas fault – fault F07 happened 3 times in the last 24 hours

A05Fan error – tachometer signal interrupted for 1 hour or longer
A06

No flame after the ignition phase – electrode error, flame unstable, incorrect valve gas offset or flue gas circuit obstructed

A41Flow sensor error – sensor disconnected
A42

Flow sensor error – sensor damaged

F07

High fume temperature – the exchanger probe detects an excessive temperature

F10

Flow sensor error – sensor damaged, short-circuited, sensor damaged or wiring broken

F11Return sensor error – t-sensor damaged, short-circuited, sensor damaged or wiring broken
F13

Exchanger probe error – t-sensor damaged, short-circuited, sensor damaged or wiring broke

F14

Flow sensor error – t-sensor damaged, short-circuited, sensor damaged or wiring broken

F15

Fan problem – tachometer signal interrupted fan connection or damaged debris in fan. You need to check and clean fan debris

F34Supply voltage under 170v – electric supply error
F35Irregular mains frequency – electric supply problem
F37Incorrect system water pressure error – possible sensor damaged or pressure too low
F43

Exchanger protection activation – no system circulation air in the system

F52Flow sensor – fault sensor damaged
A61Controller ABM03B error – controller has an internal error
A62

No communication between controller and gas valve – controller not connected or valve damaged

A63 – A64 – F66Controller ABM03B error – controller internal error

Ferroli Modena HE Combi Error Codes

Fault CodeSystem Behaviour
A01No burner ignition – possibly no gas, detection or ignition electrode fault, defective gas valve, incorrect inlet gas pressure
A02

Flame detected with the burner off – possibly caused by ionisation, defective electrode or mainboard defective. Check the printed circuit board (PCB) or ionizing electrode wiring

A03

High limit protection – flow temperature sensor not active, incorrectly located or no system circulation. Check the position of the flow sensor or check pump and radiator valves

A04Flue gas fault – could be because F07 happened 3 times in the last 24 hours – check the flue
A05Fan problem – tachometer signal interrupted for 1 hour or longer – check the wiring and the fan
A06

No flame after ignition phase – possible causes: detection electrode fault, flame unstable, incorrect valve gas offset, flue gas circuit

A41Flow sensor disconnected – check the correct positioning and operation of the flow sensors
A42Flow sensor fault – sensor needs changing
F07

High fume temperature – the exchanger probe detects an excessive temperature for over 2 minutes – check the exchanger.

F10

Flow sensor fault – possible causes: sensor damaged, short-circuited or wiring broken check the wiring

F11

Return sensor fault – sensor wiring shorted or broken – check the wiring

F12Domestic hot water (DHW) sensor fault – sensor damaged, wiring shorted or wiring disconnected – check the wiring
F13

Exchange probe fault – wiring shorted or wiring broken – check wiring

F14

Fan problem – tachometer signal interrupted fan connection. Fan damaged or debris in fan – check the wiring, the fan and clean debris

F15

Supply voltage under 170v – electric supply problem – the electrical system needs checking

F34

Irregular mains frequency – possible electric supply problem – the electrical system needs checking

F35

Incorrect system water pressure – the possible cause is pressure too low or sensor damaged – the system may need filling or check the sensor

F37

External probe fault sensor damaged or short-circuited – check the wiring

F39

Exchanger protection activation – possibly caused by no system circulation, the air in the system or sensor damaged

F43

Flow sensor fault – sensor damaged – sensor needs changing

F52Controller 041049G0 fault – controller internal error
A61No communication between controller and gas valve controller – could not be connected or valve damaged
A62Controller 041049G – internal error
A63 – A64 – F66 Controller DBM12 fault

Ferroli Discontinued Boiler Error Codes

DOMIcondens HE 26 C
OPTIMAX HE PLUS 31C boiler
OPTIMAX HE PLUS 38C boiler

BoilersFault CodeSystem Behaviour
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA01No burner ignition
OPTIMAX HE PLUS 38CA01The burner fails to light
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA02Flame present signal with burner off, possible electrical fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA03Over-temperature protection activation
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA04Fume thermostat fault
OPTIMAX HE PLUS 38CA04Fume extraction duct safety device activation
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31CA05Fan fault or fume pressure switch fault
OPTIMAX HE PLUS 38CA05Fan protection activated
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA06No flame after the ignition phase
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF07High fume temperature
DOMIcondens HE 26 CF07Card parameter
DOMIcondens HE 26 CA09Gas value fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF10Delivery sensor 1 fault
DOMIcondens HE 26 CF11DHW sensor fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF11Return sensor fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF13Fume sensor fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF14Delivery sensor 2 fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF15Fan fault
DOMIcondens HE 26 CA16Gas valve fault
DOMIcondens HE 26 CF20Combustion control fault
DOMIcondens HE 26 CA21Poor combustion fail
DOMIcondens HE 26 CA23

Set nominal system water pressure not reached within 4 minutes

DOMIcondens HE 26 CA244 fillings within 24 hours
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA34Supply voltage under 170V / 180V
DOMIcondens HE 26 CA35

Faulty mains frequency

OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA35Mains frequency anomaly
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA37Incorrect system water pressure
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA39External probe fault
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA41Sensor positioning
DOMIcondens HE 26 C / OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CF42Heating sensor fault
DOMIcondens HE 26 CA43

Exchange protection activation

DOMIcondens HE 26 CA50Gas valve fault
DOMIcondens HE 26 CA51Poor combustion fault
OPTIMAX HE PLUS 31C boiler / OPTIMAX HE PLUS 38CA62

No communication between electronic controller and gas valve  